Thumb operation.
spring return.
Dual-axis operation at any angle in any direction.
Hall contactless detection.
A variety of handles can be selected.
Switching output optional.
★Product Features
★Application
This series of products is mainly used in various operation handles, operation panels, and satellite remote control.
★Technical Information
①Electrical parameters:
Power supply current
5 ± 0.5Vdc
Electrical angle
± 25 °
Maximum supply current
10mA
Median output voltage
2.5 ± 0.1V
Linear error of output voltage
< ± 0.2V
Limit allowable overvoltage
30Vdc
Reverse limit allowable voltage
-15Vdc
②Mechanical parameters:
Rocking angle
Mode of operation
Automatic spring return
Starting force
about 2N
Operating force
about 5N
Limiting force
about 100N
Service life
> 1 million times
Weight
about 18g
③Environmental parameters:
Working temperature
-30 ℃ ~ + 70 ℃
Storage temperature
-40 ℃ ~ + 85 ℃
Protection grade
IP68?(above the installation panel)
★Dimensions
★Product Installation
★Electrical Connections