Hall has no contact angle detection.
Friction positioning, with mechanical lock in the middle position or starting point.
Wide supply voltage range.
★Product? Features
★Application
This series of products are mainly used in mining machinery and engineering vehicles.
★Technical Information
①Electrical parameters:
Hall type
Power supply voltage
5 ± 0.5Vdc
Power supply current
<11mA
Limit allowable voltage
30Vdc
Reverse limit allowable voltage
-15Vdc
Median output voltage
2.5 ± 0.1V
Linear error of output voltage
<± 0.2V
With conversion circuit
9 ~ 18Vdc (U 11 ~ U 15);
18 ~ 36Vdc (U 21 ~ U 25)
Power consumption current
20mA
②Mechanical parameters:
Rocking angle
± 30 °, ± 35 °, ± 45 °
Operation method
Friction positioning
Starting force
28N (14N, BH upper end)
Maximum operating force
28N (30N, BH upper end)
Limiting force
> 300N
Service life
about 1 million times
Weight
450g (no upper end)
③Environmental parameters:
Working temperature
-30 ℃ ~ + 70 ° ℃
Storage temperature
-40 ℃ ~ + 85 ℃
Protection grade
IP54 (BH upper end)
IP65 (other upper end)
★Dimensions
★Product Installation
★Electrical? Connections